Notifications
You must be signed in to change notification settings - Fork 20
Allowing the ability to force a sensor pod as a leak sensor #101
base: master
Are you sure you want to change the base?
Conversation
Thanks for the pull requests! I've been thinking about updating this plugin to support device-specific configurations... so that devices like this can work out of the box, rather than users having to rely on configuration options. Would you mind sharing the JSON for the device? |
The Json from winkathome? |
Yes, the JSON from winkathome would be great. BTW, I just published version |
So wink actually doesn’t see the sensors as a leak sensor either. Just a contact sensor. |
I'm thinking we can categorize weird devices by manufacturer/product name or something though. |
{
"last_event": {
"brightness_occurred_at": null,
"loudness_occurred_at": null,
"vibration_occurred_at": null
},
"object_type": "sensor_pod",
"object_id": "424998",
"uuid": "25acccd2-289c-42bd-84d4-97bb8a22be24",
"created_at": 1510709957,
"updated_at": 1534010683,
"icon_id": null,
"icon_code": null,
"desired_state": {},
"last_reading": {
"opened": true,
"opened_updated_at": 1525815613.9481874,
"battery": 1.0,
"battery_updated_at": 1510709960.2297821,
"connection": false,
"connection_updated_at": 1534255428.4678955,
"agent_session_id": null,
"agent_session_id_updated_at": null,
"firmware_version": "1.0b01 / 5.1b00",
"firmware_version_updated_at": 1510709960.2297821,
"firmware_date_code": "����������������",
"firmware_date_code_updated_at": 1510709960.2297821,
"opened_changed_at": 1525815613.9481874,
"battery_changed_at": 1510709960.2297821,
"connection_changed_at": 1526103644.0507164,
"firmware_version_changed_at": 1510709960.2297821,
"firmware_date_code_changed_at": 1510709960.2297821
},
"subscription": {
"pubnub": {
"subscribe_key": "***",
"channel": "***"
}
},
"sensor_pod_id": "424998",
"name": "Kitchen Sink",
"locale": "en_us",
"units": {},
"hidden_at": null,
"capabilities": {
"is_generic": true,
"home_security_device": true,
"sensor_types": [
{
"type": "boolean",
"field": "opened",
"mutability": "read-only"
},
{
"type": "percentage",
"field": "battery",
"mutability": "read-only"
}
],
"desired_state_fields": []
},
"triggers": [],
"manufacturer_device_model": "generic_zigbee",
"manufacturer_device_id": null,
"device_manufacturer": "generic_zigbee",
"model_name": "Generic Zigbee Sensor",
"upc_id": "322",
"upc_code": "generic_zigbee_sensor_pod",
"primary_upc_code": "generic_zigbee_sensor_pod",
"gang_id": null,
"hub_id": "509242",
"local_id": "86",
"radio_type": "zigbee",
"linked_service_id": null,
"lat_lng": [
***,
***
],
"location": "****"
} |
Ok I like that idea, could basically start or use (if one exists) a Zigbee/Z-Wave Device Type Database. |
Hmmm, ok - I didn't realize all the attributes would just say "generic_zigbee". |
eed9e48
to
be3bd25
Compare
I currently have 2 smartthings leak sensors that were showing up as contact sensors in HomeKit and Wink. This patch allows you to force a contact sensor to be a leak sensor like you can with outlets.