-
Notifications
You must be signed in to change notification settings - Fork 30k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
src: don't reset embeder signal handlers #47188
Merged
Merged
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Review requested:
|
nodejs-github-bot
added
c++
Issues and PRs that require attention from people who are familiar with C++.
needs-ci
PRs that need a full CI run.
labels
Mar 21, 2023
dvyukov
commented
Mar 21, 2023
bnoordhuis
approved these changes
Mar 21, 2023
The only bad handler value we can inhert from before exec is SIG_IGN (any actual function pointer is reset to SIG_DFL during exec). If that's the case, we want to reset it back to SIG_DFL. However, it's also possible that an embeder (or an LD_PRELOAD-ed library) has set up own signal handler for own purposes (e.g. profiling). If that's the case, keep it intact. Fix nodejs#47013
dvyukov
force-pushed
the
dvyukov-sigaction-fix
branch
from
March 22, 2023 08:40
07cb9ef
to
b82360a
Compare
@bnoordhuis please re-approve CI run. |
github-actions
bot
removed
the
request-ci
Add this label to start a Jenkins CI on a PR.
label
Mar 24, 2023
18 tasks
bnoordhuis
added
request-ci
Add this label to start a Jenkins CI on a PR.
and removed
needs-ci
PRs that need a full CI run.
labels
Mar 31, 2023
github-actions
bot
removed
the
request-ci
Add this label to start a Jenkins CI on a PR.
label
Mar 31, 2023
jasnell
approved these changes
Mar 31, 2023
bnoordhuis
added
the
commit-queue
Add this label to land a pull request using GitHub Actions.
label
Mar 31, 2023
nodejs-github-bot
removed
the
commit-queue
Add this label to land a pull request using GitHub Actions.
label
Mar 31, 2023
Landed in 37af5f5 |
RafaelGSS
pushed a commit
that referenced
this pull request
Apr 5, 2023
The only bad handler value we can inhert from before exec is SIG_IGN (any actual function pointer is reset to SIG_DFL during exec). If that's the case, we want to reset it back to SIG_DFL. However, it's also possible that an embeder (or an LD_PRELOAD-ed library) has set up own signal handler for own purposes (e.g. profiling). If that's the case, keep it intact. Fix #47013 PR-URL: #47188 Reviewed-By: Ben Noordhuis <[email protected]> Reviewed-By: James M Snell <[email protected]>
Merged
RafaelGSS
pushed a commit
that referenced
this pull request
Apr 6, 2023
The only bad handler value we can inhert from before exec is SIG_IGN (any actual function pointer is reset to SIG_DFL during exec). If that's the case, we want to reset it back to SIG_DFL. However, it's also possible that an embeder (or an LD_PRELOAD-ed library) has set up own signal handler for own purposes (e.g. profiling). If that's the case, keep it intact. Fix #47013 PR-URL: #47188 Reviewed-By: Ben Noordhuis <[email protected]> Reviewed-By: James M Snell <[email protected]>
RafaelGSS
pushed a commit
that referenced
this pull request
Apr 7, 2023
The only bad handler value we can inhert from before exec is SIG_IGN (any actual function pointer is reset to SIG_DFL during exec). If that's the case, we want to reset it back to SIG_DFL. However, it's also possible that an embeder (or an LD_PRELOAD-ed library) has set up own signal handler for own purposes (e.g. profiling). If that's the case, keep it intact. Fix #47013 PR-URL: #47188 Reviewed-By: Ben Noordhuis <[email protected]> Reviewed-By: James M Snell <[email protected]>
RafaelGSS
pushed a commit
that referenced
this pull request
Apr 8, 2023
The only bad handler value we can inhert from before exec is SIG_IGN (any actual function pointer is reset to SIG_DFL during exec). If that's the case, we want to reset it back to SIG_DFL. However, it's also possible that an embeder (or an LD_PRELOAD-ed library) has set up own signal handler for own purposes (e.g. profiling). If that's the case, keep it intact. Fix #47013 PR-URL: #47188 Reviewed-By: Ben Noordhuis <[email protected]> Reviewed-By: James M Snell <[email protected]>
danielleadams
pushed a commit
that referenced
this pull request
Jul 6, 2023
The only bad handler value we can inhert from before exec is SIG_IGN (any actual function pointer is reset to SIG_DFL during exec). If that's the case, we want to reset it back to SIG_DFL. However, it's also possible that an embeder (or an LD_PRELOAD-ed library) has set up own signal handler for own purposes (e.g. profiling). If that's the case, keep it intact. Fix #47013 PR-URL: #47188 Reviewed-By: Ben Noordhuis <[email protected]> Reviewed-By: James M Snell <[email protected]>
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
The only bad handler value we can inhert from before exec is SIG_IGN
(any actual function pointer is reset to SIG_DFL during exec).
If that's the case, we want to reset it back to SIG_DFL.
However, it's also possible that an embeder (or an LD_PRELOAD-ed
library) has set up own signal handler for own purposes
(e.g. profiling). If that's the case, keep it intact.
Fix #47013