Skip to content

1.15.37

Compare
Choose a tag to compare
@i2van i2van released this 17 Sep 17:40

Hourglass Changes

Installer

Portable

Ngen Support

Processing the Hourglass with the Native Image Generator (Ngen.exe) speeds up the Hourglass startup.

To run script as an Administrator press Win+X and select the Windows PowerShell (Admin) or Command Prompt (Admin). Copy script full path to the console opened and execute one of the following:

  • Generate the Hourglass native image and its dependencies and install in the native image cache:
ngen-Hourglass.bat install
  • Delete the native images of the Hourglass and its dependencies from the native image cache:
ngen-Hourglass.bat uninstall

Command-line

  • New command pause
  • New command resume
  • New option --digital-clock-time, -c, /c
  • New option --multi-timers, -mt, /mt
  • New option --activate-next, -an, /an
  • New option --show-trigger-time, -st, /st
  • New option --pause-after-loop-timer, -pl, /pl
  • Renamed option --prompt-on-exit to --prompt-on-close

See command-line usage for details.

UI

  • Uses a Windows Task Dialog instead of a message box (GitHub).
  • The Command-line usage dialog can be accessed from the About dialog and vice versa.
  • New Accent theme which uses Windows accent color. This theme is a default one.

Notification Area

  • All the timers are arranged by the time left. The order of the timers is new, expired, paused, running.
  • The red circle is shown over the notification area icon if at least one timer is expired.
  • The pause sign is shown over the notification area icon if at least one timer is paused.
  • The digits from 0 to 9 are the hotkeys for the timers in the notification area icon context menu.
  • The Double Click shows/hides all the timer windows.
  • The Ctrl+Click creates a new timer.
  • The Shift+Click shows the first timer.
  • The Middle Click or Shift+Right Click opens the timer options menu.
  • The Pause all menu command pauses all the running timers.
  • The Resume all menu command resumes all the paused timers.
  • The Options menu command opens the timer options menu. The shortcut is the Middle Click or Shift+Right Click on the notification area icon.
  • The Silent mode disables all the timers notifications. It is not preserved between runs.
  • The Exit menu command prompts for closing all the running timer windows if the Prompt on close option is set.
  • ⏸⏹⏏🔁 symbols are used for Paused, Stopped, Expired, Looped.

Timer Windows

Keyboard Shortcuts

  • The Esc shortcut minimizes the timer window.
  • The F11 shortcut makes the timer window full screen and back.
  • The Ctrl+N shortcut creates a new timer window.

Context Menu

  • All the timer window commands are available in the timer window context menu.
  • The shortcuts are displayed in the timer window context menu.
  • The Window title submenu is available directly from the timer window context menu.
  • The Reset position and size menu command sets the timer window default position and size.
  • The Restore, Minimize and Maximize timer window commands are always present in the timer window context menu.
  • The Advanced options / Display time in the digital clock format timer window context menu option toggles the displayed time digital clock time format. The command-line option is --digital-clock-time, -c, /c
  • The Advanced options / Show trigger time timer window context menu option shows the trigger time in the timer window and in the notification area context menu. The command-line option is --show-trigger-time, -st, /st
  • The Advanced options / Activate next window when minimized or closed timer window context menu option enables the next timer window activation when the current timer window is minimized or closed. The command-line option is --activate-next, -an, /an
  • The Pause all timer window context menu command pauses all the running timers. Command-line command is pause
  • The Resume all timer window context menu command resumes all the paused timers. Command-line command is resume
  • The Pause after each loop timer window context menu command pauses the loop timer when it expires. Command-line command is --pause-after-loop-timer, -pl, /pl

Other

  • All the timer windows are arranged by the time left. The order of the timer windows is new, expired, paused, running.
  • The minimum timer window size is limited by the Windows only.
  • The timer tooltip is shown if the timer window size is too small.
  • The progress bar changes direction to vertical when the height is more than the width and vice versa.
  • When the timer window is minimized or closed the next visible non-minimized timer window is activated.
  • The time left is now used for editing instead of the original launch time.
  • The timer window pops up on the current virtual desktop.
  • The mouse double-click on progress border toggles full screen.
  • The sound file can be placed to the %LOCALAPPDATA%\Hourglass or %LOCALAPPDATA%\Hourglass\Sounds directories. It can be the symbolic link created by the mklink system command.

Misc

Full Changelog: 1.15.36...1.15.37