feat(plc4j/modbus): Cleaned up and added some more code comments expl…
Browse files Browse the repository at this point in the history
…aining why things are done the way they are.
  • Loading branch information
chrisdutz committed Feb 22, 2022
1 parent 51657e8 commit 13d53e6
Show file tree
Hide file tree
Showing 2 changed files with 17 additions and 9 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -112,7 +112,21 @@ private void executeDiscovery(CompletableFuture<PlcDiscoveryResponse> future, Pl
final OutputStream outputStream = socket.getOutputStream();
final InputStream inputStream = new BufferedInputStream(socket.getInputStream());

// Iterate over all possible unit-identifiers
// As we not only need to provide the IP but also the unit-identifier, we need
// to iterate over all possible values until we find one that works.
// Unfortunately the way devices react to invalid requests differ:
// - My heating system doesn't sends an error response for an invalid uint-identifier
// - The Modbus Server on a S7 simply accepts any unit-identifier
// - Modbus pal only responds to correct unit-identifiers and doesn't send anything
// for invalid ones.
//
// So-far the only way I have found to reliably check if a Modbus device exists,
// was by trying to read a coil or register. Even if Modbus generally supports
// commands for diagnosing connections, it turns out none of these were actually
// supported by any device I came across. The spec is a bit unclear here, but
// it seems as if these are only supported on Serial (Modbus RTU)
// TODO: We should probably not only try to read a coil, but try any of the types and if one works, that's a match.
// Possibly we can fine tune this to speed up things.
int transactionIdentifier = 1;
for(short unitIdentifier = 1; unitIdentifier <= 247; unitIdentifier++) {
ModbusTcpADU packet = new ModbusTcpADU(transactionIdentifier++, unitIdentifier,
Expand Down Expand Up @@ -177,21 +191,15 @@ private void executeDiscovery(CompletableFuture<PlcDiscoveryResponse> future, Pl
ModbusTcpADU response = ModbusTcpADU.staticParse(readBuffer, true);
PlcDiscoveryItem discoveryItem;
if (!response.getPdu().getErrorFlag()) {
//final ModbusPDUReadDeviceIdentificationResponse identificationResponse =
// (ModbusPDUReadDeviceIdentificationResponse) response.getPdu();
// TODO: Unfortunately we need to find a device that's actually correctly responding to this request in order to implement this.
discoveryItem = new DefaultPlcDiscoveryItem(
"modbus", "tcp", possibleAddress.getHostAddress(), Collections.singletonMap("unit-identifier", Integer.toString(unitIdentifier)), "known");
"modbus", "tcp", possibleAddress.getHostAddress(), Collections.singletonMap("unit-identifier", Integer.toString(unitIdentifier)), "unknown");
discoveryItems.add(discoveryItem);

// Give a handler the chance to react on the found device.
if(handler != null) {
handler.handle(discoveryItem);
}
break;
/*} else {
final ModbusPDUError errorPdu = (ModbusPDUError) response.getPdu();
logger.info("Got error at address: {} with unit-identifier {} error {}", possibleAddress, unitIdentifier, errorPdu.getExceptionCode().toString());*/
}
} catch (ParseException e) {
// Ignore.
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -238,7 +238,7 @@
// Remark: Even if the Modbus spec states that supporting this type of request is mandatory
// I have not come across a single device that really supported it. Some devices just reacted
// with an error, however the Modbus support of my S7 1200 just terminates the connection.
// with an error.
['false','0x2B','false' ModbusPDUReadDeviceIdentificationRequest
[const uint 8 meiType 0x0E]
[simple ModbusDeviceInformationLevel level ]
Expand Down