Esphome SDM enery meter custom component

This is a fully-working example of reading data from SDM enetry meter using device with Esphome firmware.

In this implementation I am using HardwareSerial to read data from SDM, because it's more stable than SoftwareSerial.

You should use TTL to RS485 converter and connect RX port of converter to TX port of Esphome device and TX port of converter to RX port of Esphome device.

This component uses the SDM library from https://github.com/reaper7/SDM_Energy_Meter

Example

Configuration

# load the component
external_components:
  - source: github://depuits/esphome-SDM-enery-meter

# disable logging
logger:
  baud_rate: 0

# uart setup
uart:
  tx_pin: TX
  rx_pin: RX
  baud_rate: 9600
  stop_bits: 1

# sdm sensor component setup
sensor:
- platform: sdm

  # optional parameters with defaults
  baud_rate: 9600
  tx_pin: TX
  rx_pin: RX
  channel: 1
  dere_pin: 16 # -1 is disabled

  # sdm registers to read and report
  sdm_phase_1_voltage:
    name: "Voltage"
  sdm_phase_1_current:
    name: "Current"
  sdm_phase_1_power:
    name: "Power"
  sdm_import_active_energy:
    name: "Energy import"

Schematic

Schematic of ESP32 mini using MAX485

Register list for SDM devices

Register config name Register address Unit SDM630 SDM230 SDM220 SDM120CT SDM120 SDM72D
sdm_phase_1_voltage 0x0000 V 1 1 1 1 1
sdm_phase_2_voltage 0x0002 V 1
sdm_phase_3_voltage 0x0004 V 1
sdm_phase_1_current 0x0006 A 1 1 1 1 1
sdm_phase_2_current 0x0008 A 1
sdm_phase_3_current 0x000A A 1
sdm_phase_1_power 0x000C W 1 1 1 1 1
sdm_phase_2_power 0x000E W 1
sdm_phase_3_power 0x0010 W 1
sdm_phase_1_apparent_power 0x0012 VA 1 1 1 1 1
sdm_phase_2_apparent_power 0x0014 VA 1
sdm_phase_3_apparent_power 0x0016 VA 1
sdm_phase_1_reactive_power 0x0018 VAr 1 1 1 1 1
sdm_phase_2_reactive_power 0x001A VAr 1
sdm_phase_3_reactive_power 0x001C VAr 1
sdm_phase_1_power_factor 0x001E 1 1 1 1 1
sdm_phase_2_power_factor 0x0020 1
sdm_phase_3_power_factor 0x0022 1
sdm_phase_1_angle 0x0024 Degrees 1 1 1 1
sdm_phase_2_angle 0x0026 Degrees 1
sdm_phase_3_angle 0x0028 Degrees 1
sdm_average_l_to_n_volts 0x002A V 1
sdm_average_line_current 0x002E A 1
sdm_sum_line_current 0x0030 A 1
sdm_total_system_power 0x0034 W 1 1
sdm_total_system_apparent_power 0x0038 VA 1
sdm_total_system_reactive_power 0x003C VAr 1
sdm_total_system_power_factor 0x003E 1
sdm_total_system_phase_angle 0x0042 Degrees 1
sdm_frequency 0x0046 Hz 1 1 1 1 1
sdm_import_active_energy 0x0048 kWh/MWh 1 1 1 1 1 1
sdm_export_active_energy 0x004A kWh/MWh 1 1 1 1 1 1
sdm_import_reactive_energy 0x004C kVArh/MVArh 1 1 1 1 1
sdm_export_reactive_energy 0x004E kVArh/MVArh 1 1 1 1 1
sdm_vah_since_last_reset 0x0050 kVAh/MVAh 1
sdm_ah_since_last_reset 0x0052 Ah/kAh 1
sdm_total_system_power_demand 0x0054 W 1 1
sdm_maximum_total_system_power_demand 0x0056 W 1 1
sdm_current_system_positive_power_demand 0x0058 W 1
sdm_maximum_system_positive_power_demand 0x005A W 1
sdm_current_system_reverse_power_demand 0x005C W 1
sdm_maximum_system_reverse_power_demand 0x005E W 1
sdm_total_system_va_demand 0x0064 VA 1
sdm_maximum_total_system_va_demand 0x0066 VA 1
sdm_neutral_current_demand 0x0068 A 1
sdm_maximum_neutral_current 0x006A A 1
sdm_line_1_to_line_2_volts 0x00C8 V 1
sdm_line_2_to_line_3_volts 0x00CA V 1
sdm_line_3_to_line_1_volts 0x00CC V 1
sdm_average_line_to_line_volts 0x00CE V 1
sdm_neutral_current 0x00E0 A 1
sdm_phase_1_ln_volts_thd 0x00EA % 1
sdm_phase_2_ln_volts_thd 0x00EC % 1
sdm_phase_3_ln_volts_thd 0x00EE % 1
sdm_phase_1_current_thd 0x00F0 % 1
sdm_phase_2_current_thd 0x00F2 % 1
sdm_phase_3_current_thd 0x00F4 % 1
sdm_average_line_to_neutral_volts_thd 0x00F8 % 1
sdm_average_line_current_thd 0x00FA % 1
sdm_total_system_power_factor_inv 0x00FE 1
sdm_phase_1_current_demand 0x0102 A 1 1
sdm_phase_2_current_demand 0x0104 A 1
sdm_phase_3_current_demand 0x0106 A 1
sdm_maximum_phase_1_current_demand 0x0108 A 1 1
sdm_maximum_phase_2_current_demand 0x010A A 1
sdm_maximum_phase_3_current_demand 0x010C A 1
sdm_line_1_to_line_2_volts_thd 0x014E % 1
sdm_line_2_to_line_3_volts_thd 0x0150 % 1
sdm_line_3_to_line_1_volts_thd 0x0152 % 1
sdm_average_line_to_line_volts_thd 0x0154 % 1
sdm_total_active_energy 0x0156 kWh 1 1 1 1 1 1
sdm_total_reactive_energy 0x0158 kVArh 1 1 1 1 1
sdm_l1_import_active_energy 0x015A kWh 1
sdm_l2_import_active_energy 0x015C kWh 1
sdm_l3_import_active_energy 0x015E kWh 1
sdm_l1_export_active_energy 0x0160 kWh 1
sdm_l2_export_active_energy 0x0162 kWh 1
sdm_l3_export_active_energy 0x0164 kWh 1
sdm_l1_total_active_energy 0x0166 kWh 1
sdm_l2_total_active_energy 0x0168 kWh 1
sdm_l3_total_active_energy 0x016a kWh 1
sdm_l1_import_reactive_energy 0x016C kVArh 1
sdm_l2_import_reactive_energy 0x016E kVArh 1
sdm_l3_import_reactive_energy 0x0170 kVArh 1
sdm_l1_export_reactive_energy 0x0172 kVArh 1
sdm_l2_export_reactive_energy 0x0174 kVArh 1
sdm_l3_export_reactive_energy 0x0176 kVArh 1
sdm_l1_total_reactive_energy 0x0178 kVArh 1
sdm_l2_total_reactive_energy 0x017A kVArh 1
sdm_l3_total_reactive_energy 0x017C kVArh 1
sdm_current_resettable_total_active_energy 0x0180 kWh 1 1
sdm_current_resettable_total_reactive_energy 0x0182 kVArh 1
sdm_current_resettable_import_energy 0x0184 kWh 1
sdm_current_resettable_export_energy 0x0186 kWh 1
sdm_import_power 0x0500 W 1
sdm_export_power 0x0502 W 1