Add voltage and amperage scale calibration #1439
Conversation
To me is a good idea, but I don't see it in the middle of the battery tab. I think is better to have a little modal window, that shows this option. Can you look for example to the OSD tab to see how the font manager window is being done to see if it is possible to do something in this way? @mikeller, what do you think? |
I thought about making a separate window like that, but to me it is unnecessary for just one setting and a save button. If there were more settings related to this then it would be a good idea. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I think that this is a good idea, but I agree with @McGiverGim that the current UX is confusing, and that this should better be done with a modal dialog: Add a 'calibrate' button, pop open a dialog with the help text and the input and a 'Calibrate' button, and update the scale when a user clicks 'Calibrate'.
Note that the amperage popup should also tell the user that the offset needs to be measured / entered before using this calibration, or else it will not work correctly.
I just added the modal dialog with its button near Save, to me it looks okay. Maybe I could make the note a bit better to understand. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Thanks for the modal window! This looks far better.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Good job! At least it's a good first version 😁
I added the confirmation dialog showing the new calibrated scales with option to apply or discard them. Applying them will only save the new scale values and not other settings that user might have changed in power tab. |
I totally removed saving from the calibration and now when they are applied they only get set as an input value and must be saved by clicking save on power tab. |
Calibrate button should be there if there is at least one scale that can be calibrated. When you change voltage or amperage source it gets hidden because that source setting is not saved. After saving it will appear again if any of sources support scaling. |
Now I changed how showing/hiding works. Calibrate button is always shown in bottom bar if there is a scale to calibrate, but when opened it shows warnings if battery not plugged in or sources have changed but haven't been saved. It should work with just voltage or amperage or both. I added checks to remove input if voltage/amperage are less than 0.1, meaning reading is invalid or meter source is incorrect. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
This is working fine now, good work!
There is one stray whitespace, and once this is fixed it will need to be rebased / squashed into one commit.
I fixed the whitespace and rebased it. |
Adds voltage meter scale calibration by setting the actual battery voltage.
Setting the parameter to anything but zero will adjust scale automatically after saving.